| SimDis Expert® Software Version |
"Lite" | "Advanced" | "Multi-Channel" | "MS" |
Simulated Distillation Methods | X | X | X | X |
ASTM D2887 (low, extended and high temperature) | X | X | X | X |
ASTM D3710 | X | X | X | X |
ASTM D5307 | X | X | X | X |
ASTM D5399 | X | X | X | X |
ASTM D6352 | X | X | X | X |
ASTM D7096 | X | X | X | X |
ASTM D7169 | X | X | X | X |
ASTM D7213 | X | X | X | X |
ASTM D7398 | X | X | X | X |
ASTM D7500 | X | X | X | X |
ASTM D2425 | X | X | X | X |
ASTM D7807 | X | X | X | X |
DIN 51435 | X | X | X | X |
IP 406 | X | X | X | X |
IP 480 | X | X | X | X |
IP 507 | X | X | X | X |
IP 545 | X | X | X | X |
ISO 3924 | X | X | X | X |
EN 15199-1 | X | X | X | X |
EN 15199-2 | X | X | X | X |
EN 15199-3 (proposed method) | X | X | X | X |
LUBE | X | X | X | X |
Crude by External Standard (low, extended and high temperature) | X | X | X | X |
|
Key
Software Capabilities | | | | |
Cut points can be defined by user | X | X | X | X |
ASTM D-86 and D-1160 correlations can be optimized for D-2887
and D3710 | X | X | X | X |
Liquid/Vapor Ratio (D-3710) | X | X | X | X |
Reid Vapor Pressure (D-3710) | X | X | X | X |
Gases (D-3710) | X | X | X | X |
Motor Oil Volatility (MOV) (LUBE) | X | X | X | X |
Recovery (all methods ) | X | X | X | X |
On screen peak identification – allows the user to visually verify and correct time
calibrations if needed; the retention time chromatogram is displayed with
component names at the apex of each identified peak.Typing is not required to make corrections | X | X | X | X |
On-screen sample analysis – sample chromatograms, calculations and plots are all
displayed on the same screen | X | X | X | X |
Printed reports can be customized | X | X | X | X |
User access levels can be defined for enhanced security | X | X | X | X |
Multiple stored reports can be compared on screen or on paper;
and compared to sample being analyzed | | X | X | X |
Several chromatograms can be overlaid for comparative purposes | X | X | X | X |
Calculations and plots are automatically updated when the start
and/or end of the elution mark is changed by the operator ‘on-screen’ | X | X | X | X |
The elution detection algorithm is automatically adjusted (it
‘learns’) based on user defined elution marks | X | X | X | X |
A ‘blank’ chromatogram can be changed or removed during sample
analysis | X | X | X | X |
The boiling point table can be customized.Any ‘percent off’ value can be added to or
removed from the table. | X | X | X | X |
Resolution points can be customized | X | X | X | X |
Expanded integration parameters are available | X | X | X | X |
Enhanced baseline algorithm; this option enhances the shape of
the blank signal before it is subtracted from the sample chromatogram | X | X | X | X |
An alternate algorithm can be used for samples with slow elution
instead of the standard ASTM procedure | X | X | X | X |
End of the sample can be established based on the retention time
of the last carbon in the calibration | X | X | X | X |
The signal can be zeroed and/or chromatogram shift can be
defined when negative time slices are encountered | X | X | X | X |
Correlation points can be added and optimized by the user | X | X | X | X |
Carbon numbers can be used to define
cut points | X | X | X | X |
Carbon number vs. percent off can be plotted | X | X | X | X |
Volume calculations are available for crude samples | X | X | X | X |
ASCII reports are available and fully customizable for use with
other software applications | X | X | X | X |
Report comparisons can be exported to ASCII or Excel | X | X | X | X |
Screen/user interface layout color can be modified to suit the
user | X | X | X | X |
English and Spanish language support | X | X | X | X |
Multiple channels can be monitored during the same analytical
run | | | X | X |
Carbon | | | X | X |
Sulfur | | | X | X |
Nitrogen | | | X | X |
Hydrogen | | | X | X |
Other (can be defined) | | | X | X |
Sample blending simulation(s) can be performed | | X | X | X |
Boiling point correction by Detailed Hydrocarbon Analysis (DHA) | | X | X | X |
Average and percent standard deviation calculations are
available when comparing results, reports | X | X | X | X |
Ratios are available for comparative purposes | X | X | X | X |
Multiple cut point tables can be generated | | X | X | X |
Cut points can be individually labeled | X | X | X | X |
Graphic view (bar and line charts) of the cut point tables | X | X | X | X |
"Views" can be sent to clipboard or Windows Enhanced
Metafiles for use with other software programs | X | X | X | X |
Baseline signal can be viewed along with the sample signal | X | X | X | X |
Special procedure(s)/programs can be automatically executed if
there’s a QC failure | | X | X | X |
Results can be automatically exported to Microsoft Excel | X | X | X | X |
Built in peak integrator (not forced to use the one the GC
manufacturer provides with their data acquisition software ex. ChemStation) | X | X | X | X |
The distillation is 'interactive'.That is, the percent distilled and
temperature can be noted at any point during the ongoing sample analysis | X | X | X | X |
NOACK volatility calculation per DIN 51581-2 | X | X | X | X |
The ‘skewness’ associated with multiple peaks is measured | X | X | X | X |
The response factors for multiple components is measured | X | X | X | X |
CETANE Index is determined per ASTM-D976 or ASTM D-4737 | X | X | X | X |
Calculated Flash Point | X | X | X | X |
Available distillation chart depicting temperature and time
along the X axis | X | X | X | X |
Built in e-mail system; does not require MS Outlook (or other)
software to be installed | | X | X | X |
‘Reverse
baseline subtraction’; an option which can be activated in the parameter file
to instruct the software to hold off sample processing until a blank has been
acquired.This is useful in high
temperature methods when using a blank after the sample has been analyzed is
often preferred and not the one run prior to the sample. | X | X | X | X |
Automatic detection of ‘quenching window’; When this option
is activated in the parameter file, an algorithm is automatically used to
identify the beginning and end of the solvent peak | X | X | X | X |
Manual/graphical adjustment of the ‘quenching window’.The markers denoting the beginning and end
of the solvent peak can be adjusted on-screen by the user | X | X | X | X |
Y-axis added to the retention time signal | X | X | X | X |
Components reported as gases (per D-7096) can be selected | X | X | X | X |
The sample name is included when
exporting a comparison table | X | X | X | X |
Multiple reports can be combined into a single .pdf file | | X | X | X |
Ability to analyze saturated and aromatic compounds by MS | | | | X |