SimDis Expert® Software Version
"Lite""Advanced""Multi-Channel""MS"
Simulated Distillation MethodsXXXX
ASTM D2887 (low, extended and high temperature)XXXX
ASTM D3710XXXX
ASTM D5307XXXX
ASTM D5399XXXX
ASTM D6352XXXX
ASTM D7096XXXX
ASTM D7169XXXX
ASTM D7213XXXX
ASTM D7398XXXX
ASTM D7500XXXX
ASTM D2425XXXX
ASTM D7807XXXX
DIN 51435XXXX
IP 406XXXX
IP 480XXXX
IP 507XXXX
IP 545XXXX
ISO 3924XXXX
EN 15199-1XXXX
EN 15199-2XXXX
EN 15199-3 (proposed method)XXXX
LUBEXXXX
Crude by External Standard (low, extended and high temperature)XXXX
 
Key Software Capabilities    
Cut points can be defined by userXXXX
ASTM D-86 and D-1160 correlations can be optimized for D-2887 and D3710XXXX
Liquid/Vapor Ratio (D-3710)XXXX
Reid Vapor Pressure (D-3710)XXXX
Gases (D-3710)XXXX
Motor Oil Volatility (MOV) (LUBE)XXXX
Recovery (all methods )XXXX
On screen peak identification – allows the user to visually verify and correct time calibrations if needed; the retention time chromatogram is displayed with component names at the apex of each identified peak.Typing is not required to make correctionsXXXX
On-screen sample analysis – sample chromatograms, calculations and plots are all displayed on the same screenXXXX
Printed reports can be customizedXXXX
User access levels can be defined for enhanced securityXXXX
Multiple stored reports can be compared on screen or on paper; and compared to sample being analyzed XXX
Several chromatograms can be overlaid for comparative purposesXXXX
Calculations and plots are automatically updated when the start and/or end of the elution mark is changed by the operator ‘on-screen’XXXX
The elution detection algorithm is automatically adjusted (it ‘learns’) based on user defined elution marksXXXX
A ‘blank’ chromatogram can be changed or removed during sample analysisXXXX
The boiling point table can be customized.Any ‘percent off’ value can be added to or removed from the table.XXXX
Resolution points can be customizedXXXX
Expanded integration parameters are availableXXXX
Enhanced baseline algorithm; this option enhances the shape of the blank signal before it is subtracted from the sample chromatogramXXXX
An alternate algorithm can be used for samples with slow elution instead of the standard ASTM procedureXXXX
End of the sample can be established based on the retention time of the last carbon in the calibrationXXXX
The signal can be zeroed and/or chromatogram shift can be defined when negative time slices are encounteredXXXX
Correlation points can be added and optimized by the userXXXX
Carbon numbers can be used to define cut pointsXXXX
Carbon number vs. percent off can be plottedXXXX
Volume calculations are available for crude samplesXXXX
ASCII reports are available and fully customizable for use with other software applicationsXXXX
Report comparisons can be exported to ASCII or ExcelXXXX
Screen/user interface layout color can be modified to suit the userXXXX
English and Spanish language supportXXXX
Multiple channels can be monitored during the same analytical run  XX
Carbon  XX
Sulfur  XX
Nitrogen  XX
Hydrogen  XX
Other (can be defined)  XX
Sample blending simulation(s) can be performed XXX
Boiling point correction by Detailed Hydrocarbon Analysis (DHA) XXX
Average and percent standard deviation calculations are available when comparing results, reportsXXXX
Ratios are available for comparative purposesXXXX
Multiple cut point tables can be generated XXX
Cut points can be individually labeledXXXX
Graphic view (bar and line charts) of the cut point tablesXXXX
"Views" can be sent to clipboard or Windows Enhanced Metafiles for use with other software programsXXXX
Baseline signal can be viewed along with the sample signalXXXX
Special procedure(s)/programs can be automatically executed if there’s a QC failure XXX
Results can be automatically exported to Microsoft ExcelXXXX
Built in peak integrator (not forced to use the one the GC manufacturer provides with their data acquisition software ex. ChemStation)XXXX
The distillation is 'interactive'.That is, the percent distilled and temperature can be noted at any point during the ongoing sample analysisXXXX
NOACK volatility calculation per DIN 51581-2XXXX
The ‘skewness’ associated with multiple peaks is measuredXXXX
The response factors for multiple components is measuredXXXX
CETANE Index is determined per ASTM-D976 or ASTM D-4737XXXX
Calculated Flash PointXXXX
Available distillation chart depicting temperature and time along the X axisXXXX
Built in e-mail system; does not require MS Outlook (or other) software to be installed XXX
‘Reverse baseline subtraction’; an option which can be activated in the parameter file to instruct the software to hold off sample processing until a blank has been acquired.This is useful in high temperature methods when using a blank after the sample has been analyzed is often preferred and not the one run prior to the sample.XXXX
Automatic detection of ‘quenching window’; When this option is activated in the parameter file, an algorithm is automatically used to identify the beginning and end of the solvent peakXXXX
Manual/graphical adjustment of the ‘quenching window’.The markers denoting the beginning and end of the solvent peak can be adjusted on-screen by the userXXXX
Y-axis added to the retention time signalXXXX
Components reported as gases (per D-7096) can be selectedXXXX
The sample name is included when exporting a comparison tableXXXX
Multiple reports can be combined into a single .pdf file XXX
Ability to analyze saturated and aromatic compounds by MS   X